**Component**: OPC-UA extractor · `EUInformation` handling

Related products:Extractors
  • August 24, 2026
  • 1 reply
  • 20 views

**Component**: OPC-UA extractor · `EUInformation` handling

 

**Current behaviour** (confirmed by Cognite): the extractor never reads `NamespaceUri` or

`UnitId` from `EUInformation`. The only value that reaches any config surface is the

composed `DisplayName: Description` string. The UNECE code is dropped before

`metadata-mapping` can see it, so `unit` / `unitExternalId` resolution to a

`CogniteUnit` from the source unit is impossible today and is not planned.

 

**Request**: carry `UnitId` through, and resolve the CDF `unit` direct relation from it.

 

**Why it matters to us**: across our fleet the `unit` direct relation is populated on

**0 of 2772** time series, while 528 of 854 at one line carry the composed string in

`sourceUnit`. The only path available is post-processing that string-matches against the

CDF unit catalogue. That is brittle in exactly the way a code-keyed lookup is not —

`kW·h: kilowatt hour` has to be parsed and matched by display text, and it will differ

by server locale, by punctuation (`kW·h` vs `kWh`), and by however each gateway's

engineer typed the description. `UnitId` is an integer-ish UNECE code designed for

precisely this lookup.

 

**Also useful even without resolution**: expose `UnitId` as a `metadata-mapping` source

so consumers can do the mapping themselves deterministically.

1 reply

Jørgen Lund
Expert ⭐️⭐️⭐️⭐️
Product Manager
August 31, 2026

Hi ​@APSHANKAR Sagar!

Thank you for suggesting this product idea. We will follow the traction this idea gets in the community. You can expect updates on this post if we decide to include this in our future roadmap, or if we require more information.